Rig Out Get a free quote →
A chiller module sits under insulated overhead piping beside a yellow caged ladder in a mechanical room.A heat-recovery chiller plant: modular chiller units under large insulated pipe mains in a mechanical room.A long row of air-cooled condensing units with fan guards stretching along a gravel yard.An industrial cooling tower hangs from a mobile crane's boom on a spreader bar and slings against an open sky.

WHAT WE MOVE · CHILLERS & REFRIGERATION

Chillers and refrigeration equipment

Chillers, coolers, cooling towers, refrigeration racks and rooftop units. A licensed refrigeration technician takes the refrigerant out first. Then our crew frees the unit, lifts it once, hauls it and sets it level, and licensed trades reconnect it.

The load

Full of fluid, bolted down and a long way up

A chiller holds fluid and gas, sits bolted to a roof curb or a pad, and is often three storeys above the trailer it has to land on.

A close view of a cooling tower's rigging straps as it is lifted above a roof.
A white insulated condenser-water return pipe with a flow arrow rises beside a cabinet unit in a mechanical room
Insulated pipe and a stainless duct run along a green-floored mechanical mezzanine.

01 · Refrigerant and fluids

Out before anything is disconnected

A licensed refrigeration technician recovers the charge, the refrigerant inside the unit, into cylinders before the unit is disconnected, and the recovery is recorded. Chilled water, glycol and compressor oil are drained and captured. None of it goes down a floor drain.

02 · Weight and lifting points

Heavy at the compressor end

The manufacturer's rigging drawing shows where a unit can be lifted, and that is where we lift it. A spreader bar holds the slings apart, so they stay off the tube bundles, the control panel and the coils. Towers and rooftop units lift from their base rails or lugs. The casing looks like a handle. It isn't.

03 · Coils and accessories

The parts that bend

A coil can dent and leak if a sling or a fork so much as touches it. Fans, fill, pumps, panels and field piping are separated, protected and tagged, so what belongs with the unit goes with the unit.

A large cooling-tower module sits secured on a multi-axle lowboy trailer in an open yard under a clear blue sky.
A crane truck sets a cooling unit onto the rooftop of a blue-clad industrial building under a blue sky.
A picker truck with its crane extended, front three-quarter view in snow.

How we move it

Disconnect, lift, haul and set

01 · Before the lift

The disconnect, in order

The charge is recovered, the power is locked out by a licensed electrician, the piping is drained and capped, and the gas is isolated by a licensed gas fitter. Those are licensed sub-trades that we hire and manage as general contractor, under your permits. Then the anchors come free. The order is set at the site walk with your mechanical contractor, so the roof is not opened to weather before the lift is ready.

02 · The lift

Off the roof in one pick

Most units are one crane lift: off the curb, the raised frame it sits on, over the parapet, the low wall at the roof edge, and onto a trailer. There is a lift plan, one signaller and an exclusion zone, the ground kept clear under the load. Where a crane cannot reach, it is specialty rigging, or our lift trucks across a plant floor.

03 · On the road

Blocked, capped and wrapped

A chiller rides on its base rails, and the chains go to the frame, never over a coil. Pipe stubs are capped and the unit is wrapped against grit and salt. Towers travel in sections on our own trucks. A unit that arrives early waits indoors in warehousing.

04 · The set

Set, level, connect

The unit goes down on its pad, isolators or curb and is levelled to the manufacturer's tolerance. Licensed trades then reconnect and start it, managed by us the same way as the disconnect. Our crew stays on site in case anything has to shift an inch. See Installation.

A long interior cultivation room with rolling bench tables running to a vanishing point beneath spiral ductwork, ceiling air handlers and wall fans.
A long packaged air-handling unit with copper and steel piping runs along the wall of a building mechanical room.
Long aluminum panels stacked flat with timber spacers, banded and strapped on skids in a clean yard, ready to ship.

Where it fits

Buildings, plants and the next owner

Chillers, towers and rooftop units are mostly commercial work. Process chillers, glycol systems and refrigeration racks are industrial and agricultural. A unit coming out for good goes under equipment and plant removal, and one that still has work in it can go on to a new owner through equipment sales. Bought a unit at a sale? See auction rig-outs. A whole mechanical plant runs as a site move.

FAQ

Questions we get

Who recovers the refrigerant?

A licensed refrigeration technician, hired and managed by us, into cylinders, before the unit is disconnected. The recovery is recorded.

Can you get a chiller off a roof without closing the street for a day?

Most units are one crane lift onto a trailer in the lane beside the building. The lift plan sets the crane position, the radius and the exclusion zone, so the lane is closed only as long as the lift needs.

Can the new unit go up the same day the old one comes down?

Often, yes. The new unit goes up on the same crane set-up, which is why we plan the change-out as one job with your mechanical contractor.

The chiller is in a basement with no crane access. What then?

That is specialty rigging. The chiller is jacked up and rolled out on skates, the low rollers that slide in underneath, with a gantry over it to lift from above and a route out through a knock-out panel, a removable section of wall.

Who starts the unit at the new site?

Licensed mechanical and refrigeration trades reconnect and start it. We set and level the unit, then manage those trades under your permits.

Got a chiller that has to come down?

Send us the nameplate, where it sits and where it is going.

Email sales@rigout.ca.

sales@rigout.ca