Rig Out Get a free quote →
Gas compressor buildings with large cooler fans, exhaust stacks and a tower behind them at a facility under a blue sky.A bank of six wall-hung gas boilers on a steel rack under insulated piping in a mechanical room.An insulated tank with a bank of wall-mounted drive panels and insulated piping in a mechanical room.Insulated pipe and a stainless duct run along a green-floored mechanical mezzanine.

WHAT WE MOVE · COMPRESSORS & MECHANICAL

Compressors and mechanical

Compressors, air handlers, boilers, pumps and whole mechanical rooms. Our crew gets them off the pad, out through the building, onto our own trucks and set level at the next site.

The load

Heavier than it looks, and still wet

Air and gas compressors, air handlers, boilers, pumps, heat exchangers and the piping between them. One piece or the whole room. We also move chillers and refrigeration equipment.

A control valve and grey process piping inside a metal-clad equipment building.
A wide, empty, fully stripped interior room with a bare concrete floor and a large round spiral duct along the ceiling.
A long, symmetrical room with overhead ducting and stacked metal racking along both sides of a polished floor.

01 · Weight

Low, off-centre and hidden

A compressor package carries its weight at one end. A boiler carries it in the shell and in the refractory, the heat-proof lining inside. The weight on the nameplate is the dry weight, and what sits on the pad is wet. We find the real centre of gravity before anything lifts.

02 · Fluids

Oil, glycol, water, fuel

Each one is drained, captured and documented before the move. The scope sets out who does the draining. A unit shipped wet leaks on the trailer, and the trailer has somewhere to be afterwards.

03 · Fragile parts

Coils, fins, controls

Coils and fins bend at a touch, and refractory cracks under shock. Gauges and sensor lines stick out exactly where a sling wants to run. We protect them, take off what can come off, and route the rigging around the rest.

Rows of large insulated pipe runs and ductwork along the wall and ceiling of an industrial plant room.
An overhead view of an air-handling unit with silver ductwork and wiring in a plant room.
A long, bright room seen from one end with a gridded floor of low trays and tidy overhead ducting and pipework.

How we move it

Isolate, plan the route, lift and set

01 · Isolation

Nothing live, hot or full

A licensed electrician locks out the power and a licensed gas fitter isolates the gas. They are licensed sub-trades that we hire and manage as general contractor, under your permits, unless the scope gives that work to your own licensed trades. Steam and hot water are cooled and drained, and air receivers, the compressed-air tanks, are vented to zero. Our own locks go on the points that matter to the lift, and we walk the isolation with you before the crew starts. See Safety.

02 · The route

The room decides the method

We measure the doors, corridors and stairs and check what the floor will carry. A pump goes out on a lift truck. A compressor rolls out on skates, the low rollers that slide in underneath. A boiler in a basement is specialty rigging. Anything leaving over the wall is a crane lift with a written plan.

03 · The lift and the haul

From the frame, not the sheet metal

We lift from the shipping lugs, or build the pick from the base frame where there are none. A pump skid lifts from the skid and never from the pump. On our trucks the piece is blocked and chained and its open connections are capped. For a long haul it is sealed under crating and shrink wrap.

04 · The set

Level, anchored and aligned

The piece is set on shims, the thin plates that take up an uneven pad, then levelled and anchored to the manufacturer's pattern. On a coupled pump or a belt-driven compressor we align driver to driven, the motor to the machine it turns, and record the readings. Licensed trades reconnect it, managed by us, and we stay through start-up. That is installation work.

A wide cleared bay with framed yellow walls, steel columns and an open concrete floor.
A packaged air-handling unit with white piping on a green-painted mechanical room floor
A long packaged air-handling unit with copper and steel piping runs along the wall of a building mechanical room.

Where it fits

Buildings, plants and lease sites

A mechanical-room move is usually part of a machinery move, a site move or an equipment removal ahead of a sale through equipment sales. Most of it is commercial and industrial, plus energy sites where gas compressors come off lease skids. Every piece carries its tag through Traceability. If you bought the piece at a sale and need it out, see auction rig-outs.

FAQ

Questions we get

Who does the lockout before you start?

A licensed electrician and a licensed gas fitter isolate the equipment first. We hire and manage them, unless the scope gives that work to your own licensed trades. We hang our own locks on the points that matter to the lift and walk the isolation with your representative before the crew starts.

Does the compressor or boiler have to be drained first?

Yes. Oil, boiler water, glycol and fuel are drained, captured and documented before the move. The scope sets out who does it.

How do you get a boiler out of a basement or an air handler off a mezzanine?

That is specialty rigging: jacking and rolling, a gantry over the piece to lift it from above, stair-climbers, or a floor opening you have agreed to. We measure the route at the site walk and pick the method from there.

The lifting lugs were cut off years ago. Can you still lift it?

Yes. We build the pick from the base frame, with cribbing, stacked blocking, under the structural members and not under the sheet metal or the coils.

Do you align the pump to its motor at the new site?

Yes. We align driver to driven and record the readings, because a pump set out of alignment eats its own bearings.

Got a mechanical room to empty?

Send us the nameplate, a few photos of the room and where it is going.

Email sales@rigout.ca.

sales@rigout.ca
CallEmailFree quote